MCS TECHNOLOGY
SYSTEM SPECIFICATIONS

 
   
Energy Input 1.87 MBTUs / Unit
Treatment Chamber Capacity 5 CY or 6.0 - 7.5 Ton Capacity / Unit
Dimensions 20'L x 8.5'W x 8'H / Unit
Standard System Components Desorber, Controls, Ducting, Condensate Pumps, Condenser, Impenger, Flame Foils, Carbon Absorber
Additional Emission Components for Special Projects Electrostatic Precipitator, Scrubbers, HEPA Filtration, Thermal Oxidizer
Infrared Burner System Feuls Natural Gas, Propane, Butane and Fuel Oil
Solids Temperature 100° F - 1400° F
Indirect or Direct Fired Desorber
Nondestructive Treatment and Recovery Process
Power Requirements 460 Volt 3 Phase
Vacuum

0" - 21" Hg

Purge Gas Volume 1,000 - 3,000 CFM
 
   
   
   
   
   